Kalstein

Consumables, Spare Parts, and Accessories for the YR05645-1 Horizontal Pulsating Vacuum Autoclave

By Kalstein · Published on:

Category:articulos-de-productos

Consumables, Spare Parts, and Accessories for the YR05645-1 Horizontal Pulsating Vacuum Autoclave

Discover the essential consumables, spare parts, and accessories compatible with the YR05645-1 Horizontal Pulsating Vacuum Autoclave. Enhance its functionality

Consumables, Spare Parts, and Accessories for the YR05645-1 Horizontal Pulsating Vacuum Autoclave

Consumables, Spare Parts, and Accessories for the YR05645-1 Horizontal Pulsating Vacuum Autoclave

The YR05645-1 Horizontal Pulsating Vacuum Autoclave offers advanced sterilization capabilities, making it a critical asset in various laboratory settings. To ensure optimal performance and longevity, it's essential to understand the necessary consumables, spare parts, and accessories that can enhance the functionality and reliability of this model. In this article, we will delve deep into these components, offering insights on their specifications, compatibility, and recommended usage.

Understanding the YR05645-1: An Overview

The YR05645-1 model is designed for efficient sterilization using a combination of pulsating vacuum techniques and built-in steam generation. This horizontal autoclave is particularly well-suited for applications in clinical, industrial, and educational laboratories. To maximize its utility, various compatible consumables and accessories must be utilized, which will be explored in the following sections.

Technical Specifications of YR05645-1

FeatureDescription
ModelYR05645-1
TypeHorizontal Pulsating Vacuum Autoclave
Pressure Design-0.1/0.25Mpa
Temperature Design139℃
Working Temperature Range105℃-136℃
Maximum Working Pressure0.23Mpa
Drying FunctionVacuum Drying
Weight460kg
Power12kw

Compatible Consumables for YR05645-1

To maintain the YR05645-1 autoclave's performance, various consumables are essential for ensuring effective sterilization. The following consumables are recommended:

  • Steam Generator Water: Use distilled or deionized water to prevent mineral buildup within the steam generator.
  • Autoclave Bags: High-temperature resistant sterilization bags designed to withstand the autoclaving process.
  • Indicators: Chemical and biological indicators to monitor the effectiveness of the sterilization process.
  • Filter Paper: Used for filtration of liquids before autoclaving.
  • Sealants: Compatible sealants for maintaining the integrity of containers during the sterilization process.

Recommended Spare Parts for Maintenance

Regular maintenance of the YR05645-1 is vital to prevent unexpected downtimes. Below is a list of recommended spare parts:

  • Door Seals: Replace every 6 months to prevent steam leaks.
  • Heating Elements: Regularly check for performance and replace if inefficiencies arise.
  • Pressure Gauges: Ensure accurate readings by replacing every year.
  • Vacuum Pump Oil: Change regularly to maintain optimal vacuum performance.
  • HEPA Filters: Change every 12 months to ensure effective filtration.

Accessories to Enhance Functionality

Several accessories can augment the functionality of the YR05645-1, making it suitable for various applications:

  • Track and Hold Software: For advanced sterilization cycle tracking and documentation.
  • Calibration Kits: To ensure accurate readings and compliance with standards.
  • External Printer: For easy access to sterilization reports and data.
  • Additional Trays: For efficient loading and sterilization of multiple items.

Maintenance Schedule for YR05645-1

A well-defined maintenance schedule is crucial for the effective operation of the autoclave:

TaskFrequency
Check door sealsEvery 6 months
Replace heating elementsAs required
Change vacuum pump oilEvery 3 months
Replace HEPA filtersEvery 12 months
Perform calibration checksAnnually

Frequently Asked Questions

What type of water should be used in the YR05645-1 autoclave?

It is recommended to use distilled or deionized water in the YR05645-1 to prevent mineral buildup in the steam generator, which can affect performance and efficiency.

How often should the door seals of the YR05645-1 be replaced?

The door seals should be inspected regularly and replaced every 6 months to ensure that there are no steam leaks, which can compromise the sterilization process.

What indicators should be used to verify the effectiveness of the sterilization process in the YR05645-1?

Chemical and biological indicators are recommended to monitor the sterilization process, ensuring that items are effectively sterilized before use.

Are there any specific maintenance tasks that need to be performed on the YR05645-1?

Yes, regular maintenance tasks include checking the door seals, replacing heating elements as needed, changing the vacuum pump oil every three months, and replacing HEPA filters annually to maintain optimal performance.

What accessories can enhance the performance of the YR05645-1?

Accessories such as track and hold software, calibration kits, external printers, and additional trays can enhance the functionality and usability of the YR05645-1 autoclave.

What is the recommended frequency for changing the HEPA filters in the YR05645-1?

HEPA filters should be changed every 12 months to ensure effective filtration and maintain the integrity of the sterilization process.

How can I request a quote for the YR05645-1 autoclave and its accessories?

You can easily request a quote by reaching out to our sales team or using our online platform for immediate access to pricing and availability.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Horizontal Pulsating Vacuum Autoclave with Touch Screen YR05645-1 with all specifications, dimensions, accessories and quote options.
View product datasheet →