The YR05646-1 Horizontal Pulsating Vacuum Autoclave is a sophisticated piece of laboratory equipment designed for reliable sterilization processes. To maintain its high performance and longevity, it is critical to utilize the appropriate consumables, spare parts, and accessories. This guide will delve into the essential components required for optimal operation of the YR05646-1, ensuring that users understand the importance of quality consumables and the specifications for compatibility.

Technical Specifications of YR05646-1

ModelBrandCategorySubcategoryPrice (USD)Price (EUR)Gross WeightDimensions
YR05646-1KalsteinAutoclaveHorizontal Autoclave8485.0016471580 kg1680 x 1080 x 2100 mm

Key Consumables for YR05646-1

The performance of the YR05646-1 can significantly depend on the quality of consumables used during its operation. Below are essential consumables that should be regularly checked and replaced:

  • Steam Generator Water: Clean, distilled water is necessary for the steam generator to function efficiently. It should be replaced every 300 sterilization cycles to avoid mineral buildup.
  • HEPA Filter: The built-in HEPA filter, specified at 0.22um, should be replaced every year or after 1000 cycles to ensure effective air filtration.
  • Silicone Door Gaskets: To maintain a proper seal, door gaskets should be inspected for wear and replaced every two years.

Spare Parts for Maintenance

Regular maintenance and timely replacement of spare parts ensure continued reliability of the YR05646-1. Consider keeping the following spare parts on hand:

  • PLC Control Unit: If the control unit malfunctions, having a spare on hand reduces downtime.
  • Vacuum Pump: A backup vacuum pump is essential for immediate replacement in case of operational failures.
  • Pressure Relief Valve: Regular inspection and timely replacement of the pressure relief valve will prevent safety hazards.

Recommended Accessories

The following accessories can enhance the functionality of the YR05646-1 autoclave:

  • Tray Accessories: Various sterilization trays designed for different instrument sizes can optimize the sterilization cycle.
  • Additional Printing Supplies: Extra rolls of thermal paper are necessary for the built-in printer to ensure documentation of each sterilization cycle.
  • Calibration Weights: For calibration purposes, specific weights must be used to ensure accurate pressure and temperature readings.

Compatibility Chart for Consumables and Accessories

ItemTypeReference CodeReplacement Interval
Steam Generator WaterConsumableWater-STDEvery 300 cycles
HEPA FilterConsumableFilter-HEPA-0.22Every 1000 cycles or annually
Silicone Door GasketSpare PartGasket-SIL-01Every 2 years
Tray AccessoriesAccessoryTray-ACCAs needed
Thermal Paper RollAccessoryPaper-ROLLAs needed

Frequently Asked Questions

What are the critical consumables for the YR05646-1 autoclave?

The critical consumables for the YR05646-1 include steam generator water, HEPA filters, and silicone door gaskets. These ensure optimal performance and safety during sterilization processes.

How often should the HEPA filter be replaced in the YR05646-1?

The HEPA filter should be replaced every year or after 1000 sterilization cycles to maintain efficient air filtration and prevent blockages that may affect performance.

Are there any specific spare parts recommended for the YR05646-1?

Yes, it is advisable to have a spare PLC control unit, vacuum pump, and pressure relief valve on hand for quick replacements in case of failure, ensuring minimal downtime.

What are some recommended accessories for the YR05646-1?

Recommended accessories include sterilization trays, additional printing supplies, and calibration weights to enhance functionality and ensure accurate measurements during operation.

How do I ensure the longevity of the YR05646-1?

To ensure longevity, regular maintenance, timely replacement of consumables and spare parts, as well as using high-quality accessories are essential practices.

Can I customize the YR05646-1 with additional features?

Yes, optional modules and software upgrades may be available to enhance the capabilities of the YR05646-1 depending on specific operational needs.

Where can I find more information about purchasing the YR05646-1 and its accessories?

You can request a quote on Kalstein Plus for the YR05646-1 and its compatible accessories to get detailed pricing and specifications.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.