Kalstein

Operation Lamp YR02134

Operation Lamp YR02134

The Operation Lamp YR02134 combines technical features for laboratory routines, operational continuity and a coherent equipment selection process.

This page provides an overview of the Operation Lamp YR02134, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.

This Kalstein model is available for laboratories in United Kingdom, with selection criteria adapted to local purchasing, installation and support conditions.

Ver más

Key factors to consider

Key factors to consider

Before selecting the Operation Lamp YR02134, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.

Its use is oriented to laboratory routines that require observation, control and operational continuity.

For the market in United Kingdom, evaluation should consider local context such as NHS, university research, UKCA/CE marking and match the product to the real workload of the laboratory.

Market price range

Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.

The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.

In United Kingdom, budget comparison should include CE references, 230V/50Hz power conditions, accessories, logistics and after-sales support.

Value for money

Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.

Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.

Advantages and disadvantages

Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.

Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.

Expected lifespan based on use and maintenance

Expected lifespan based on use and maintenance

Model YR02125 YR02126 YR02127 YR02128 YR02129 YR02130 YR02131 YR02132 Head Diameter (mm) 700 500 500/500 500 300 No. Of LEDs 80 units 48 units 80 units 160 units 80 units 25 units Illumination (Lux) 160000 140000 100000 ≥100,000/100,000 ≥60,000 ≥70,000 CRI (Ra) Ra>95 Ra>85 92 Color Temperature (K) 3500-5000 4800±300 4500±500 4800±200 Illumination Depth (mm) 1200 ≥500 300 Spot Diameter (mm) 120-300 160-220 150 LED Life (h) 50,000 hours Model YR02133 YR02134 YR02135 YR02136 YR02137 YR02138 YR02139 YR02140 Head Diameter (mm) 300 250 300 100 No.

Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.

Support and spare-parts availability oriented to United Kingdom helps preserve service continuity and plan preventive maintenance without extended downtime.

Specifications table for the Operation Lamp YR02134

Operation Lamp YR02134

Operation Lamp YR02134

Nuestro concepto operativo ergonómico y estéril permite un control sencillo y flexible de todas las funciones por parte del equipo quirúrgico. La esperanza de vida casi ilimitada de los LED ofrece una enorme fiabilidad del producto y protección de la inversión. Proactivo con el medio ambiente: el bajo consumo de energía y los LED duraderos minimizan el impacto sobre nuestros preciados recursos.
Características
  • Modo Endo.
  • Iluminación profunda.
  • Tecnología de regulación PWM, sin parpadeos.
  • Luz fría LED, la temperatura del cabezal sube menos de 1℃.
  • El alto índice de reproducción cromática garantiza una visión clara del tejido y del órgano.
  • Mango esterilizador extraíble.
  • Ajuste del campo luminoso.
ModelYR02125YR02126YR02127YR02128YR02129YR02130YR02131YR02132
Head Diameter (mm)700500500/500500300
No. Of LEDs80 units48 units80 units160 units80 units25 units
Illumination (Lux)160000140000100000≥100,000/100,000≥60,000≥70,000
CRI (Ra)Ra>95Ra>8592
Color Temperature (K)3500-50004800±3004500±5004800±200
Illumination Depth (mm)1200≥500300
Spot Diameter (mm)120-300160-220150
LED Life (h)50,000 hours
ModelYR02133YR02134YR02135YR02136YR02137YR02138YR02139YR02140
Head Diameter (mm)300250300100
No. Of LEDs25 units7 pieces led bulbs12 pieces led bulbs19 pieces led bulbs
Halogen bulb
Illumination (Lux)≥70,000≥3000060000≥80000≥50,000
CRI (Ra)92100≥Ra≥85≥85100≥Ra≥85-
Color Temperature (K)4800±2004500±5004500±5003500,4000,45004000±500
Illumination Depth (mm)300≥700300
Spot Diameter (mm)150View product

Frequently Asked Questions about the Operation Lamp YR02134

How do I choose the right operation lamp yr02134 for my laboratory?

Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.

What should I review before requesting a quotation?

Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.

Does Kalstein provide guidance for this type of equipment?

Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.

What maintenance helps extend the equipment lifespan?

Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.

Contact Us

Contact Kalstein