Technical Glossary and Key Terminology for the YR02194 Infant Bilirubin Phototherapy Unit
The YR02194 Infant Bilirubin Phototherapy Unit is a vital tool in neonatal care, primarily designed for the treatment of jaundice in newborns. Understanding its technical terms and functionalities is essential for healthcare professionals operating this device. This glossary aims to clarify key terminologies associated with the YR02194, thereby enhancing operational knowledge and effectiveness.
Understanding the YR02194: Key Features Overview
The YR02194 model stands out due to its mobile design, which facilitates easy maneuverability in various clinical settings. It utilizes four blue fluorescent tube bulbs that emit light in a specific wavelength range, essential for the effective treatment of neonatal jaundice. The device is equipped with a digital LED timer, allowing for precise monitoring of therapy time, which is crucial for ensuring proper treatment protocols.
Technical Specifications of YR02194
| Specification | Details |
|---|---|
| Model | YR02194 |
| Input Power | <150VA |
| Light Source | Blue Tube |
| Effective Light Source Life | 1000 hours |
| Wavelength | 400-550 nm |
| Irradiance Treatment Distance | 10~500px |
| Effective Area | 1125px×600px |
| Infrared Radiation in Effective Area | ≤10mW/cm2 (760nm<λ≤1400nm) |
| Ultraviolet Radiation in Effective Area | ≤1.0×10-5mW/cm2 (180nm<λ≤400nm) |
| Operating Noise | ≤55dB(A) (ambient noise is lower than 40dB(A)) |
| Basic Performance | Equipment total irradiance (Ebi) ≥500μW/cm2 |
| Adjust Angle | 30°, 60°, 90° |
| Adjust Height | 1100mm~1500mm |
Glossary of Technical Terms for YR02194
| Term | Definition |
|---|---|
| Bilirubin | A yellow compound that occurs in the normal catabolic pathway that breaks down heme in vertebrates. |
| Phototherapy | A medical treatment that uses light to eliminate bilirubin from the blood. |
| Irradiance | The power of light per unit area, often measured in μW/cm2, critical for determining treatment effectiveness. |
| Wavelength | The distance between successive peaks of a wave, measured in nanometers (nm); crucial for effective bilirubin breakdown. |
| Effective Area | The specific area over which the device effectively delivers light therapy. |
| Operating Noise | The sound produced by the device during operation, measured in decibels (dB). |
| Adjust Height | The capability to modify the height of the phototherapy unit to accommodate various treatment needs. |
| Digital LED Timer | A display component that shows remaining therapy time and total treatment duration. |
| Blue Tube Bulb | The specific type of bulb used in the YR02194 that emits light in the optimal wavelength range for phototherapy. |
| Mobile Design | A structural feature that allows easy movement of the unit within a clinical environment. |
Frequently Asked Questions
What is the purpose of the YR02194 Infant Bilirubin Phototherapy Unit?
The YR02194 Infant Bilirubin Phototherapy Unit is designed to treat neonatal jaundice by using light therapy to break down excess bilirubin in the blood of newborns, which is crucial for preventing potential brain damage.
How does the digital LED timer work on the YR02194?
The digital LED timer on the YR02194 displays both the remaining therapy time and the total duration of the treatment, allowing healthcare professionals to monitor and ensure proper treatment protocols are followed.
What are the effective wavelength ranges for the YR02194 unit?
The YR02194 emits light in the wavelength range of 400-550 nm, which is essential for the effective breakdown of bilirubin in newborns.
What is the significance of the adjustable height feature?
The adjustable height feature allows operators to modify the unit's height from 1100mm to 1500mm, ensuring optimal positioning for effective treatment, accommodating various configurations and patient needs.
How often should the blue tube bulbs be replaced?
The effective life of the blue tube bulbs in the YR02194 is approximately 1000 hours; therefore, they should be monitored and replaced accordingly to maintain optimal performance in phototherapy.
What maintenance is required for the YR02194?
Routine maintenance includes checking the integrity of the bulbs, ensuring the timer functions correctly, and verifying that the unit operates within the specified noise levels to ensure patient comfort and device reliability.
How can I request a quote for the YR02194 unit?
If you are interested in the YR02194 unit, you can request a quote through our dedicated channels for pricing and availability information.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.