Kalstein

Technical Glossary and Key Terminology for YR05808 Laboratory Fume Extraction Hood

By Kalstein · Published on:

Category:articulos-de-productos

Technical Glossary and Key Terminology for YR05808 Laboratory Fume Extraction Hood

Explore the essential technical terms and features related to the YR05808 laboratory fume extraction hood. Understand the specifications, common applications, a

3D available

Technical Glossary and Key Terminology for YR05808 Laboratory Fume Extraction Hood

The YR05808 laboratory fume extraction hood is an essential apparatus for maintaining a safe working environment in chemical laboratories. This article delves into the technical glossary and terminology specific to this model, ensuring users understand its components, specifications, and operational terms.

Overview of YR05808 Fume Extraction Hood

The YR05808 is designed primarily to protect laboratory personnel from hazardous fumes, vapors, and dust. Its construction involves epoxy-coated steel, which enhances durability and corrosion resistance. Understanding the terminology behind its features is crucial for effective usage.

Technical Specifications of YR05808

SpecificationDetails
ModelYR05808
External Dimensions (W x D x H)650 x 650 x 1000 mm
Internal Dimensions (W x D x H)450 x 600 x 750 mm
Working Surface Height800 mm
Maximum Window Opening750 mm
Air Velocity / Escape Air Volume0.4-0.6 m/s, 800-1000 m³/h
Noise Level≤60 dB
LED Lamp Power10W
Blower TypeIntegrated axial flow blower; adjustable speed.
Window TypeManual operator, tempered glass, adjustable height.
Power SupplyAC 220V ± 10%, 50/60 Hz;
Consumption100W
Gross Weight110 kg

Key Terminology Related to YR05808

TermDefinition
Fume HoodA ventilated enclosure designed to protect users from inhaling harmful vapors and gases generated during laboratory processes.
Epoxy CoatingA protective layer applied to the exterior of the hood to enhance durability and resistance to chemicals.
Axial Flow BlowerA fan design that moves air parallel to the shaft of the fan, providing efficient airflow necessary for fume extraction.
Tempered GlassA type of safety glass that is stronger than regular glass and can withstand high temperatures, used for the fume hood window.
Air VelocityThe speed at which air is drawn into the fume hood, critical for ensuring the safe removal of hazardous air contaminants.
Corrosion ResistanceThe ability of materials (like the epoxy-coated steel of YR05808) to withstand degradation due to chemical exposure.
Noise LevelThe sound emitted by the fume hood during operation, measured in decibels (dB), which affects user comfort.
Manual Window OperationA feature allowing users to manually adjust the height of the fume hood window for optimal airflow and safety.
Blower Speed AdjustmentThe capability to regulate the airflow through the fume hood by varying the speed of the axial flow blower.
Chemical Resistant Work SurfaceSurface designed to withstand exposure to various chemicals, ensuring longevity and safety in laboratory settings.

Frequently Asked Questions

What maintenance is required for the YR05808 fume hood?

Regular maintenance for the YR05808 includes checking and cleaning the air filters, inspecting the blower for debris, and ensuring that all electrical components are functioning properly. It is crucial to establish a routine schedule to keep the unit in optimal working condition.

How can I ensure the fume hood is functioning properly?

To verify the functionality of the YR05808, you should perform airflow tests, check for any unusual noises during operation, and ensure that the window opens and closes smoothly. Additionally, conduct a visual inspection for any signs of wear or damage.

What types of chemicals can I use within the YR05808 fume hood?

The YR05808 is suitable for a wide variety of chemicals commonly used in laboratory settings, including acids and bases. However, it is important to consult the manufacturer's guidelines regarding specific chemical compatibility and safety measures.

Are there any specific installation requirements for the YR05808?

Installation of the YR05808 requires proper ventilation, access to electrical power, and a level surface for stable operation. Additionally, ensure that there is adequate clearance around the fume hood for effective airflow and safety.

What is the lifespan of the YR05808 fume hood?

The expected lifespan of the YR05808 can vary based on usage and maintenance, but with proper care, it typically lasts several years. Regular inspections and timely repairs can extend its functional life significantly.

How does the YR05808 compare to other fume hoods?

The YR05808 is designed to offer superior airflow efficiency, noise reduction, and chemical resistance compared to traditional fume hoods. Its specific features, such as adjustable blower speed and tempered glass, enhance its operational performance and user safety.

Where can I request a quote for the YR05808?

You can easily request a quote for the YR05808 by contacting Kalstein directly. They can provide pricing information and answer any specific questions you may have about the product.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Epoxy-coated steel basic chemical laboratory fume extraction hood YR05808 with all specifications, dimensions, accessories and quote options.