The YR06168 Automatic Veterinary Chemistry Analyzer represents a significant advancement in veterinary diagnostics, offering a multitude of features tailored for efficient testing and analysis. Understanding the technical terms associated with this model not only enhances operational proficiency but also improves troubleshooting and maintenance capabilities. This article will explore essential terminology relevant to the YR06168, making it a vital resource for operators and technicians alike.

Understanding the YR06168: An Overview

The YR06168 is built to cater to the needs of veterinary clinics and laboratories, providing high-performance testing capabilities with its open reagent system and user-defined configurations. It is designed for streamlined operations and high sample throughput, featuring a robust architecture that supports a variety of veterinary applications.

Technical Specifications of the YR06168

SpecificationDetails
ModelYR06168
Reagent VolumeR1: 180-450uL, 0.1uL adjustable; R2: 3-250uL, 0.1uL adjustable
Reaction Position90 cuvettes, 10 cuvettes/strip
CuvetteOptical path length of 5mm
Reaction Volume180-500uL
Reaction Temperature37°C
LampHalogen lamp
Absorbance Range0-3.500Abs
Wavelengths8 wavelengths from 340-700 nm
Resolution0.0001Abs
Power SupplyDC 110V/220V, 50HZ/60Hz
DimensionsLength x Width x Height (mm): 630 x 480 x 510
Net Weight70kg
Sample Volume3~45uL, 0.1uL adjustable
Reagent Positions26
Refrigerated Temperature4-15°C

Key Terminology Related to the YR06168

The following glossary provides definitions for key terms that are crucial for understanding and effectively utilizing the YR06168 Automatic Veterinary Chemistry Analyzer. Familiarity with these terms will enhance operational efficiency and troubleshooting capabilities.

TermDefinition
AnalyzerAn instrument designed to perform measurements and analyses of samples.
CalibrationThe process of adjusting the accuracy of an analyzer based on known standards.
CuvetteA small, transparent container used to hold liquid samples for analysis.
ReagentA substance used to cause a chemical reaction in testing processes.
AbsorbanceA measure of the amount of light absorbed by a sample.
WavelengthThe distance between successive peaks of a wave, important in spectrophotometry.
Open SystemA configuration allowing the use of third-party reagents.
Sample ThroughputThe number of tests the analyzer can perform in a given time period.
Optical Path LengthThe length that light travels through a cuvette or sample.
Micro-volumeRefers to very small volumes of samples, typically in the microliter range.
Multilingual SoftwareSoftware capable of functioning in multiple languages to accommodate users.
Sample PositionThe location in the analyzer where the sample is placed for measurement.
Refrigerated TemperatureThe temperature range for storing reagents to maintain their integrity.

Frequently Asked Questions

What is the sample throughput of the YR06168 Automatic Veterinary Chemistry Analyzer?

The YR06168 can perform up to 100 tests per hour, significantly enhancing efficiency in veterinary diagnostics.

How does the open reagent system of the YR06168 work?

The open reagent system allows users to utilize various third-party reagents, offering flexibility in testing options and potentially lowering operational costs.

What are the benefits of using micro-volume samples in the YR06168?

The use of micro-volume samples (3~45uL) minimizes waste and reduces the cost of reagents, making the testing process more economical.

Can the YR06168 be calibrated by the user?

Yes, the YR06168 supports user calibration to ensure accuracy based on specific testing requirements.

What types of animals can be configured on the YR06168?

The analyzer comes with 8 pre-set animal configurations and allows for an unlimited number of user-defined settings, accommodating a wide range of veterinary applications.

What is the significance of the optical path length in the YR06168?

The optical path length of 5mm affects the system's sensitivity and the accuracy of absorbance readings, which are crucial for precise analysis.

How can I obtain a quote for the YR06168?

You can easily request a quote through our channels to get competitive pricing for the YR06168 Automatic Veterinary Chemistry Analyzer.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Automatic Veterinary Chemistry Analyzer YR06168 with all specifications, dimensions, accessories and quote options.
View product datasheet →