Technical Glossary and Key Terminology for the YR06168 Automatic Veterinary Chemistry Analyzer
The YR06168 Automatic Veterinary Chemistry Analyzer represents a significant advancement in veterinary diagnostics, offering a multitude of features tailored for efficient testing and analysis. Understanding the technical terms associated with this model not only enhances operational proficiency but also improves troubleshooting and maintenance capabilities. This article will explore essential terminology relevant to the YR06168, making it a vital resource for operators and technicians alike.
Understanding the YR06168: An Overview
The YR06168 is built to cater to the needs of veterinary clinics and laboratories, providing high-performance testing capabilities with its open reagent system and user-defined configurations. It is designed for streamlined operations and high sample throughput, featuring a robust architecture that supports a variety of veterinary applications.
Technical Specifications of the YR06168
| Specification | Details |
|---|---|
| Model | YR06168 |
| Reagent Volume | R1: 180-450uL, 0.1uL adjustable; R2: 3-250uL, 0.1uL adjustable |
| Reaction Position | 90 cuvettes, 10 cuvettes/strip |
| Cuvette | Optical path length of 5mm |
| Reaction Volume | 180-500uL |
| Reaction Temperature | 37°C |
| Lamp | Halogen lamp |
| Absorbance Range | 0-3.500Abs |
| Wavelengths | 8 wavelengths from 340-700 nm |
| Resolution | 0.0001Abs |
| Power Supply | DC 110V/220V, 50HZ/60Hz |
| Dimensions | Length x Width x Height (mm): 630 x 480 x 510 |
| Net Weight | 70kg |
| Sample Volume | 3~45uL, 0.1uL adjustable |
| Reagent Positions | 26 |
| Refrigerated Temperature | 4-15°C |
Key Terminology Related to the YR06168
The following glossary provides definitions for key terms that are crucial for understanding and effectively utilizing the YR06168 Automatic Veterinary Chemistry Analyzer. Familiarity with these terms will enhance operational efficiency and troubleshooting capabilities.
| Term | Definition |
|---|---|
| Analyzer | An instrument designed to perform measurements and analyses of samples. |
| Calibration | The process of adjusting the accuracy of an analyzer based on known standards. |
| Cuvette | A small, transparent container used to hold liquid samples for analysis. |
| Reagent | A substance used to cause a chemical reaction in testing processes. |
| Absorbance | A measure of the amount of light absorbed by a sample. |
| Wavelength | The distance between successive peaks of a wave, important in spectrophotometry. |
| Open System | A configuration allowing the use of third-party reagents. |
| Sample Throughput | The number of tests the analyzer can perform in a given time period. |
| Optical Path Length | The length that light travels through a cuvette or sample. |
| Micro-volume | Refers to very small volumes of samples, typically in the microliter range. |
| Multilingual Software | Software capable of functioning in multiple languages to accommodate users. |
| Sample Position | The location in the analyzer where the sample is placed for measurement. |
| Refrigerated Temperature | The temperature range for storing reagents to maintain their integrity. |
Frequently Asked Questions
What is the sample throughput of the YR06168 Automatic Veterinary Chemistry Analyzer?
The YR06168 can perform up to 100 tests per hour, significantly enhancing efficiency in veterinary diagnostics.
How does the open reagent system of the YR06168 work?
The open reagent system allows users to utilize various third-party reagents, offering flexibility in testing options and potentially lowering operational costs.
What are the benefits of using micro-volume samples in the YR06168?
The use of micro-volume samples (3~45uL) minimizes waste and reduces the cost of reagents, making the testing process more economical.
Can the YR06168 be calibrated by the user?
Yes, the YR06168 supports user calibration to ensure accuracy based on specific testing requirements.
What types of animals can be configured on the YR06168?
The analyzer comes with 8 pre-set animal configurations and allows for an unlimited number of user-defined settings, accommodating a wide range of veterinary applications.
What is the significance of the optical path length in the YR06168?
The optical path length of 5mm affects the system's sensitivity and the accuracy of absorbance readings, which are crucial for precise analysis.
How can I obtain a quote for the YR06168?
You can easily request a quote through our channels to get competitive pricing for the YR06168 Automatic Veterinary Chemistry Analyzer.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.
