Technical Glossary and Key Terminology for YR01869-2 Thermocyclers
Understanding the YR01869-2 Thermocycler
The YR01869-2 thermocycler is a sophisticated piece of laboratory equipment designed to enhance the nucleic acid extraction process through its innovative features. In this article, we will explore the essential technical terminology associated with this model, providing clarity and insight into how these terms relate to its operation and function.
Technical Specifications of the YR01869-2
| Specification | Details |
|---|---|
| Model | YR01869-2 |
| Performance | 16 |
| Processing Volume | 20-1700μL |
| Sample Processing Volume | 200-500μL |
| Compatible Consumables | Custom 96 deep well plates, individual 6 strip tubes |
| Difference Between Wells | CV≤3% |
| Mixing Method | Rotary mixing |
| Rotation Speed | 100~3000rpm |
| Temperature Control Range | Separate temperature control for lysis and elution. |
| Temperature range from 30°C to 120°C. | |
| Temperature Control Accuracy | Heating rate: 4.0±0.2°C/s. |
| Temperature accuracy: ±1.0°C. | |
| Temperature uniformity: ≤1.0°C. | |
| Languages | Chinese/English |
| Protocol Management | Flexibility to create, edit, and delete protocols |
| Operating Mode | Mode 1: Android systems on smartphones/tablets |
| Mode 2: Full-color LCD screen of 6.86 inches | |
| Automatic Control | Automatic opening and closing of the experiment chamber |
| Reagent Identification | Automatic identification of reagent information and execution of tests |
| Mixing Sleeve Supervision | Real-time control of the status of mixing sleeves in experiment |
| Magnetic Bead Residues | ≤1% |
| Power Failure Protection | Freely choose whether to continue the experiment when power is restored after outage. |
| Disinfection | Ozone + UV disinfection |
| Automatic Shutdown | Automatic shutdown after UV disinfection |
| Negative Pressure Filtration | HEPA negative pressure filtration module |
| Connection Port Type | USB port |
| Weight | 7.4Kg (net) |
| Instrument Dimensions | 210mm(L)*229mm(W)*242mm(H) |
| Power Supply | AC220V, 50Hz |
Key Terminology Glossary
| Term | Definition |
|---|---|
| Thermocycler | A laboratory device used to amplify DNA and RNA samples through the polymerase chain reaction (PCR) technique. |
| Nucleic Acid Extraction | The process of isolating nucleic acids (DNA or RNA) from biological samples for further analysis. |
| PCR (Polymerase Chain Reaction) | A method used to make multiple copies of a specific DNA segment, allowing for its analysis and study. |
| UV Disinfection | A process that uses ultraviolet light to kill or inactivate microorganisms, ensuring a sterile environment. |
| HEPA Filtration | A high-efficiency particulate air filter that traps harmful particles and contaminants in the air. |
| Rotary Mixing | A mixing method that involves rotating samples to achieve uniform dispersion. |
| Temperature Control | The ability to maintain a set temperature within a device to ensure proper reaction conditions. |
| Reagent | A substance used in a chemical reaction to detect or measure another substance. |
| Real-Time Monitoring | The ability to observe and record data as it occurs during an experiment. |
| Sample Volume | The amount of sample used in an experiment, affecting the results and accuracy of the analysis. |
| Automatic Protocol Management | A feature allowing users to create, edit, and automate experimental protocols within the device. |
| Power Outage Recovery | The functionality allowing the device to resume operations after a loss of power. |
| Compact Design | A design that minimizes the space required for the equipment, facilitating its use in various settings. |
| Screen Interface | A touch-sensitive display allowing users to interact with the device and control its functions. |
| Magnetic Beads | Small, spherical particles that can be magnetized, often used in nucleic acid extraction to facilitate separation. |
| Performance Consistency | The reliability and repeatability of the device's performance across different experiments. |
| Sample Contamination | The introduction of unwanted substances into a sample, potentially affecting the results. |
| Experiment Chamber | The enclosed area in which experiments are conducted, designed to minimize contamination and ensure controlled conditions. |
| Mobile Power Source | A portable power supply that allows the device to be used in various locations without fixed electrical connections. |
| Intuitive Interface | A user-friendly design that allows users to easily navigate and operate the device without extensive training. |
| Multi-Project Handling | The capability to manage and execute multiple experimental protocols simultaneously. |
| Advanced Protection System | A set of features designed to prevent damage or contamination, ensuring the integrity of the experiments. |
Frequently Asked Questions
What types of samples can I process with the YR01869-2 thermocycler?
The YR01869-2 thermocycler is capable of processing a wide variety of samples, especially those requiring precise nucleic acid extraction, such as DNA and RNA analyses.
Is the YR01869-2 easy to operate?
Yes, the device features a 6.86-inch touch screen and a remote control system, allowing for user-friendly operation through smartphones or tablets. The interface is intuitive, enabling quick and efficient experimentation.
How do I maintain the YR01869-2 in good condition?
It is essential to perform regular maintenance, clean the device after each use, and ensure remote system updates to maintain optimal performance.
What is the price range for the YR01869-2 thermocycler?
The YR01869-2 thermocycler is typically priced between $8,350 and $8,360, depending on the supplier and additional services included. This positions it as a significant investment for laboratories and research centers.
How can I optimize the performance of the YR01869-2?
To enhance the performance of the YR01869-2, it is recommended to follow the manufacturer’s maintenance guidelines, regularly clean the equipment, and maximize its capabilities by running multiple assays in parallel.
What are the key features of the YR01869-2 that enhance its functionality?
The YR01869-2 features include automated workflow management, remote updates for the system, UV disinfection for contamination prevention, and a compact design for portability, making it suitable for various applications.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.