Kalstein

Technical Glossary and Key Terminology of the YR01869-2 Automatic Nucleic Acid Extractor

By Kalstein · Published on:

Category:articulos-de-productos

Technical Glossary and Key Terminology of the YR01869-2 Automatic Nucleic Acid Extractor

Explore essential technical terms and key terminology related to the YR01869-2 Automatic Nucleic Acid Extractor, enhancing your understanding of its capabilitie

3D available

Technical Glossary and Key Terminology of the YR01869-2 Automatic Nucleic Acid Extractor

The YR01869-2 Automatic Nucleic Acid Extractor is a sophisticated instrument designed for optimizing nucleic acid extraction processes. This article provides a detailed technical glossary and key terminology that will enhance your understanding of the equipment's functionalities and applications.

Understanding the YR01869-2

The YR01869-2 stands out in laboratory settings due to its innovative rotary mixing technology (RMT) and automation capabilities, allowing it to perform various sample extractions simultaneously without cross-contamination. Here, we will define critical terms connected to its operation, design, and technical specifications.

Technical Specifications

ModelYR01869-2
Performance16
Processing Volume20-1700μL
Sample Processing Volume200-500μL
Compatible ConsumablesCustom 96-well deep plates, individual tubes of 6 strips
Difference Between WellsCV≤3%
Mixing MethodRotary Mixing
Rotation Speed100~3000rpm
Temperature Control RangeControl for lysis and elution separately, 30°C to 120°C
Temperature Control AccuracyHeating rate: 4.0±0.2°C/s, Temperature accuracy: ±1.0°C, Temperature uniformity: ≤1.0°C
LanguagesChinese/English
Protocol ManagementFlexibility to create, edit, and delete protocols
Operating ModesMode 1: Android systems on smartphones/tablets; Mode 2: 6.86-inch full-color LCD
Automatic ControlAutomatic opening and closing of the experimental cabinet
Reagent IdentificationAutomatic identification of reagent information and execution of assays
Mixing Sleeve MonitoringReal-time monitoring of the status of mixing sleeves in experiments
Magnetic Beads Residue≤1%
Power Failure ProtectionOption to continue the experiment after power is restored
DisinfectionOzone + UV disinfection
Automatic ShutdownAutomatic shutdown after UV disinfection
Negative Pressure FiltrationNegative pressure HEPA filtration module
Connection Port TypeUSB port
Weight7.4Kg (net)
Instrument Dimensions210mm(L) * 229mm(W) * 242mm(H)
Power SupplyAC220V, 50Hz

Key Terminology Glossary

TermDescription
Nucleic AcidBiomolecules essential for all known forms of life, including DNA and RNA.
ExtractionThe process of obtaining nucleic acids from biological samples.
Rotary Mixing Technology (RMT)A method used in the YR01869-2 to mix samples thoroughly without contamination.
Cross-ContaminationUnintended transfer of material from one sample to another, which the YR01869-2 minimizes through its design.
Temperature ControlThe ability of the YR01869-2 to maintain specific temperatures for sample processing.
Protocol ManagementThe capability to create and manage experimental protocols within the YR01869-2.
DisinfectionProcess involving UV and ozone to ensure the cleanliness of the equipment.
Sample Processing VolumeThe range of volumes the YR01869-2 can effectively process, from 200-500μL.
Compatible ConsumablesItems used in conjunction with the YR01869-2, including plates and tubes.
Real-time MonitoringThe capability of checking the operational status during experiments.
Performance MetricsStandards used to measure the efficiency and accuracy of the YR01869-2.
Automatic ShutdownThe feature that powers down the system after completing operations to conserve energy.
HEPA FiltrationA high-efficiency particulate air filter used to purify air within the YR01869-2.
USB PortThe connection interface for data transfer and device control.
WeightTotal weight of the YR01869-2, which affects its portability and installation.
Power Failure ProtectionSystem ability to recover from power interruptions without losing data or progress.

Frequently Asked Questions

What are the main applications of the YR01869-2 Automatic Nucleic Acid Extractor?

The YR01869-2 is primarily used in genetic research laboratories, clinical diagnostics, and biotechnology applications. Its design allows for efficient nucleic acid extraction from various biological samples, making it an essential tool for PCR and similar analyses.

How does the rotary mixing technology benefit the extraction process?

Rotary mixing technology enhances sample mixing efficiency while preventing contamination, allowing for high-quality nucleic acid extractions. This technology ensures uniform processing and consistent results across multiple samples.

What safety features are incorporated in the YR01869-2?

The YR01869-2 is equipped with advanced safety features, including UV disinfection and negative pressure HEPA filtration, reducing the risk of contamination and ensuring user safety during operation.

Can the YR01869-2 be connected to external software?

Yes, the YR01869-2 has a USB port that allows for connectivity with external devices and software, enabling data transfer and enhanced control capabilities.

What maintenance practices should be followed for optimal performance of the YR01869-2?

Regular cleaning, timely updates of operational protocols, and thorough checks of the filtration systems are recommended for maintaining the YR01869-2. Following the manufacturer's guidelines ensures longevity and optimal performance.

How can I request a quote for the YR01869-2?

You can easily request a personalized quote for the YR01869-2 by utilizing the quote request feature available. This allows you to receive tailored offers along with potential discounts and technical support options.

What is the expected lifespan of the YR01869-2, and how should it be replaced?

The expected lifespan varies based on usage, but regular maintenance and updates can prolong its life. Signs indicating the need for replacement include persistent errors, inability to perform standard tasks, and physical wear.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Automatic Nucleic Acid Extractor YR01869-2 with all specifications, dimensions, accessories and quote options.
View product datasheet →