Understanding the YR02954 Ceramic Hotplate Stirrer Through Technical Glossary
The YR02954 Ceramic Hotplate Stirrer is a sophisticated piece of laboratory equipment that combines precise temperature control with effective stirring capabilities. To operate this device efficiently and safely, it is essential to understand various technical terms and key terminology associated with its features and functions. This article aims to provide a comprehensive glossary that will enhance your familiarity with the YR02954.
Technical Specifications of the YR02954
| Item | Specification |
|---|---|
| Model | YR02954 |
| Material of Top Plate | White Ceramics, Square Plate |
| Stir Range | 100~1800 RPM |
| Stirring Speed Accuracy | ±1 RPM |
| Ceramic Top Dimension per Position (MM) | 180 × 180 |
| Working Time | Continuous |
| Position | 4 |
| Stirring Speed Indicator | Digital Display |
| Maximum Top Plate Temperature | 325℃ |
| Temperature Range per Position | Ambient to 400℃ |
| Temperature Accuracy | ±1 degree |
| Temperature Control | PID |
| Voltage | 160-240V |
| Temperature Display | Digital Display |
| External Thermometer | For measuring and controlling the liquid temperature along with the front panel |
| Internal Thermometer | Controls and measures the temperature of the hotplate stirrer |
| Motor Power per Position | 40W, DC20V |
| Product Power per Position | 550W |
| Stirring Capacity per Position | 50ml-5000ml |
| Body Material | Metal Superfine |
| Net Weight (KG) | 20 |
Key Terminology for the YR02954
| Term | Definition |
|---|---|
| PID Control | A method of control that uses Proportional, Integral, and Derivative calculations to maintain the desired temperature. |
| Ceramic Coating | A protective layer applied to the hotplate to enhance corrosion resistance and thermal durability. |
| Magnetic Stirring | A technique that uses a rotating magnetic field to stir liquids without direct contact. |
| Digital Display | A visual interface that shows real-time readings such as temperature and stirring speed. |
| Temperature Gradient | The rate of temperature change in a given direction, important for ensuring uniform heating. |
| Max Temperature | The highest temperature that the hotplate can reach, critical for various laboratory applications. |
| Stirring Capacity | The maximum volume of liquid that can be effectively stirred by each position on the hotplate. |
| Voltage Range | The acceptable range of electrical voltage for the proper operation of the device. |
| Net Weight | The weight of the equipment excluding packaging and other accessories. |
| Continuous Operation | This refers to the ability of the hotplate to run without interruption for extended periods. |
| Calibration | The process of adjusting the equipment to ensure accurate readings and operations. |
| Corrosion Resistance | The ability of materials to withstand degradation from chemical reactions with their environment. |
| Stirring Speed | The rate at which the agitator rotates, measured in RPM (revolutions per minute). |
| Thermometer | A device used to measure temperature, essential for monitoring the heating process. |
| Liquid Temperature Control | The ability to maintain a specific temperature of the liquid being heated or stirred. |
| Electronic Components | The internal parts of the hotplate that facilitate its digital functionalities. |
| OEM Service | Original Equipment Manufacturer service, indicating custom solutions available for the equipment. |
| Environmental Conditions | The specific conditions such as temperature and humidity that should be maintained for optimal performance. |
| Power Supply | The source of electrical power that the device requires to function correctly. |
| Front Panel | The user interface section of the device where controls and indicators are located. |
Frequently Asked Questions
What is the significance of PID control in the YR02954?
PID control is crucial for maintaining the desired temperature by continuously adjusting the heating based on the error between the setpoint and the measured temperature. It ensures stability and precise control for various laboratory applications.
How does the ceramic coating benefit the operation of the YR02954?
The ceramic coating on the top plate of the YR02954 enhances its resistance to corrosion and thermal wear, ensuring longevity and consistent performance, especially in harsh laboratory environments.
What is the maximum stirring capacity of the YR02954?
The YR02954 can effectively stir liquids ranging from 50ml to 5000ml, making it versatile for different experimental needs.
How does the digital display facilitate operation?
The digital display provides real-time feedback on temperature and stirring speed, allowing operators to monitor and adjust settings quickly for optimal results.
What are the essential safety features of the YR02954?
The YR02954 includes a specially designed casing that protects electronic components from splashes and spills, ensuring safe operation in laboratory settings.
What should I consider for optimal environmental conditions when using the YR02954?
Optimal conditions include maintaining the appropriate temperature range, humidity levels, and ensuring proper ventilation to avoid overheating or operational disruptions.
Where can I request a quote for the YR02954?
You can easily request a quote for the YR02954 by reaching out through our dedicated customer service channels to receive personalized assistance.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.