Kalstein

Technical Glossary and Key Terminology for the YR06222 Infant Phototherapy Unit

By Kalstein · Published on:

Category:articulos-de-productos

Technical Glossary and Key Terminology for the YR06222 Infant Phototherapy Unit

Explore the technical glossary and key terminology related to the YR06222 Infant Phototherapy Unit, enhancing your understanding of its operation and applicatio

3D available

Technical Glossary and Key Terminology for the YR06222 Infant Phototherapy Unit

The YR06222 Infant Phototherapy Unit offers critical functions for treating newborns with hyperbilirubinemia. Understanding the technical terms associated with this model enhances effective operation and troubleshooting. This article delves into essential terminology that operators must be familiar with to maximize the effective use of the YR06222.

Understanding the YR06222: Key Features and Functionality

The YR06222 is designed for phototherapy treatment, featuring advanced monitoring and control systems. Below are the crucial specifications that define its performance:

SpecificationDetail
ModelYR06222
Bilirubin Radiancy (4cm)3600μw/cm2(60μw/cm2/nm)
Lighting Intensity33%, 67%, 100%
White LightYes
Radiant Space360 × 210 (mm × mm)
Power≤ 100VA
Wavelength400nm ~ 550nm
Radiant Uniformity0.4
Therapy Time Set0-99h59m
Temperature Monitor Range30 - 40°C

Glossary of Key Terms Related to YR06222

TermDefinition
BilirubinA yellow compound that occurs in the metabolism of red blood cells, elevated levels indicate jaundice in infants.
PhototherapyA treatment that uses light to reduce bilirubin levels in infants with jaundice.
WavelengthThe distance between successive peaks of a wave, relevant in determining the effectiveness of light therapy.
IntensityThe power of light emitted by the phototherapy unit, adjustable to suit treatment needs.
RadiancyThe measure of the power emitted by the unit per unit area, an essential metric for phototherapy effectiveness.
UniformityThe consistency of light distribution over the treatment area, crucial for effective treatment.
Temperature MonitorA feature that ensures the infant's skin temperature remains within safe limits during treatment.
Therapy TimeThe duration for which the phototherapy unit operates, customizable based on clinical needs.
LED LightsLight Emitting Diodes used in the YR06222 for efficient and safe phototherapy.
Control SystemThe programmable aspect that allows adjustment of settings according to treatment protocols.

Importance of Understanding Terminology in the YR06222 Operation

Familiarity with the key terms associated with the YR06222 equips healthcare professionals and technicians with the knowledge necessary to utilize the device effectively. It ensures that users can follow operational guidelines, troubleshoot issues, and communicate effectively in a clinical setting.

Frequently Asked Questions

What are the main functions of the YR06222 Infant Phototherapy Unit?

The YR06222 is designed to provide effective phototherapy treatment aimed at reducing bilirubin levels in infants with jaundice. It features LED lighting, temperature monitoring, and programmable controls to optimize treatment outcomes.

How does the temperature monitoring system work in the YR06222?

The YR06222 includes a skin temperature sensor that continuously monitors the infant's body temperature, ensuring it remains within a safe range during treatment. This feature helps prevent overheating and ensures the infant's comfort.

Why is light intensity important in phototherapy?

Light intensity directly affects the efficacy of phototherapy. The YR06222 allows for adjustable intensities (33%, 67%, and 100%) to accommodate different treatment requirements and ensure optimal bilirubin reduction.

What is the significance of wavelength in the YR06222?

The wavelength of 400nm to 550nm in the YR06222 is specifically chosen to target bilirubin effectively. This range of light is optimal for phototherapeutic purposes and maximizes treatment efficacy.

How can I ensure consistent treatment outcomes with the YR06222?

To achieve consistent outcomes, operators must ensure proper setup and calibration of the YR06222, monitor treatment duration, and adjust light intensity as required. Understanding key terminology and equipment functions is crucial for effective operation.

What accessories are compatible with the YR06222?

The YR06222 is designed to work seamlessly with various accessories, including replacement LED lights, temperature sensors, and other compatible medical devices that enhance its functionality.

How do I request a quote for the YR06222?

To request a quote for the YR06222 Infant Phototherapy Unit, please contact our sales team for personalized assistance and pricing details.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Infant Phototherapy Unit YR06222 with all specifications, dimensions, accessories and quote options.
View product datasheet →