Kalstein

Veterinary Portable Anesthesia Machine YR06097: Sector Adaptations and Technical Insights 2026

By Kalstein · Published on:

Category:articulos-de-productos

Veterinary Portable Anesthesia Machine YR06097: Sector Adaptations and Technical Insights 2026

Explore the adaptations and technical insights of the Veterinary Portable Anesthesia Machine YR06097 across various sectors including clinical, industrial, and

3D available

Veterinary Portable Anesthesia Machine YR06097: Sector Adaptations and Technical Insights 2026

The Veterinary Portable Anesthesia Machine YR06097 is a compact, reliable piece of equipment designed for use in various environments, including veterinary hospitals, clinics, and educational settings. Its versatility allows it to adapt across different sectors, making it an essential tool for veterinarians and educators alike. This article delves into the technical specifications and practical applications of the YR06097, emphasizing the importance of its design and functionality in diverse clinical, industrial, and educational settings.

Technical Specifications of YR06097

SpecificationDetails
ModelYR06097
Respiration ModeManual mode, open mode, closed mode, semi-open and semi-closed mode
Gas SourceO2, quick inlet port
O2 Flush20L/min~75L/min
Flow MeterO2, 0L/min ~10L/min, easily adjustable
Airway Pressure Gauge-20cmH2O-100cmH2O
APL Valve (Pop Off Valve)Easily adjustable, range: 0-60cmH2O
Inspiration and Expiration ValvesVisible dome-type, ISO standard port, 22mm diameter
Soda Lime Chamber2 Liters, easy to change soda lime within one minute
Bains ConnectorOpen breath system, compatible with Bains circuit and Jackson circuit
Anesthesia VaporizerCompatible with Enflurane, Isoflurane, Halothane, or Sevoflurane
Auxiliary Gas Source OutputProvides gas source to anesthesia ventilator
Three MethodsTabletop, trolley, or wall-mounted type (with trolley and wall-mounted type as optional)

Sector Adaptations of YR06097

Clinical Settings

In clinical environments, the YR06097 is utilized for precise anesthesia administration during surgeries in small animals. Its compact design allows for easy transport between treatment rooms, enabling veterinarians to efficiently manage multiple surgical cases without compromising on quality. The machine's versatility in respiration modes allows practitioners to customize anesthesia delivery based on individual patient needs, making it a critical asset in any veterinary clinic.

Industrial Applications

In industrial settings, the YR06097 finds use in research facilities and animal testing labs where controlled anesthesia is vital. Its quick inlet port facilitates rapid setup and the adjustment of gas flow rates, ensuring that animals are safely anesthetized without undue stress. The machine's compatibility with various anesthetics also allows for flexibility depending on the specific requirements of the research being conducted.

Educational Use

The YR06097 serves as an invaluable teaching tool in veterinary schools. Students learn to manage anesthesia in a safe and controlled environment, gaining hands-on experience with a device that mirrors professional practice. Its straightforward setup and operation ensure that learners can focus on mastering essential skills without being overwhelmed by complex machinery.

Technical Details and Features

The Veterinary Portable Anesthesia Machine YR06097 is designed with numerous features that enhance its usability and effectiveness across sectors. The incorporation of a soda lime chamber allows for efficient CO2 absorption, which is essential during lengthy procedures. Moreover, the adjustable APL valve enables clinicians to control pressure easily, minimizing risk and optimizing patient safety.

Common Issues and Troubleshooting for YR06097

While the YR06097 is designed for reliability, users may encounter specific symptoms that require attention. The following table outlines common issues along with their probable causes and solutions:

SymptomsProbable CausesSolutions
Equipment does not power onPower source is off or faultyCheck power connections, replace the power cable if necessary
Error code E-03Gas flow interruptionInspect gas sources and quick inlet port for blockages
Inconsistent readingsCalibration required or faulty sensorsRecalibrate the device, replace sensors if problems persist

Frequently Asked Questions

What is the primary function of the Veterinary Portable Anesthesia Machine YR06097?

The YR06097 is designed to deliver controlled anesthesia to animals undergoing surgical procedures, ensuring their safety and comfort throughout the process.

How does the YR06097 adapt to different clinical practices?

The machine offers multiple respiration modes, customizable settings, and compatibility with various anesthetics, allowing it to meet the needs of different veterinary practices.

What maintenance is required for the YR06097?

Regular cleaning of the soda lime chamber, checking gas connections, and periodic calibration are crucial for maintaining the YR06097's performance.

Is there training available for using the YR06097?

Yes, many manufacturers offer training programs for veterinarians and technicians to ensure they are proficient in using the machine effectively and safely.

What accessories are compatible with the YR06097?

The YR06097 is compatible with various vaporizers and gas sources, along with optional accessories such as carts and wall mounts for improved usability.

Can the YR06097 be used in emergency situations?

Yes, the YR06097 is designed for portability and quick setup, making it suitable for emergency procedures in veterinary practices.

Where can I request a quote for the YR06097?

You can request a quote for the YR06097 directly through the Kalstein website or by contacting their sales department.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Veterinary Portable Anesthesia Machine YR06097 with all specifications, dimensions, accessories and quote options.
View product datasheet →