Kalstein

Installation and Environmental Requirements for the YR02079 Operation Theatre Ceiling Pendant

By Kalstein · Published on:

Category:articulos-de-productos

Installation and Environmental Requirements for the YR02079 Operation Theatre Ceiling Pendant

Discover the essential installation guidelines and environmental conditions for optimizing the performance of the YR02079 Operation Theatre Ceiling Pendant, ens

Installation and Environmental Requirements for the YR02079 Operation Theatre Ceiling Pendant

Installation and Environmental Requirements for the YR02079 Operation Theatre Ceiling Pendant

The YR02079 Operation Theatre Ceiling Pendant is designed for optimal functionality in clinical environments such as operating rooms, emergency rooms, intensive care units, and recovery areas. Understanding the environmental conditions and installation requirements is crucial for ensuring the pendant operates effectively and safely. This guide delves into site preparation, necessary conditions, and installation protocols for the YR02079.

Understanding the YR02079 Operation Theatre Ceiling Pendant

The YR02079 is a ceiling-mounted pendant that offers the convenience of a rotating arm, featuring a 340° rotation angle and a maximum load capacity of 160 kg. Designed to accommodate essential gas and electrical connections, its installation must be performed under specific environmental conditions to ensure operational integrity.

Technical Specifications of the YR02079

SpecificationDetails
ModelYR02079
Arm Rotating Radius800mm + 800mm
Arm Rotating Angle340°
Braking SystemFriction Brake
Maximum Load Capacity160 kg
Electrical Socket2 Earth Studs
Standard Configuration1 Oxygen (O2), 1 Air, 1 Vacuum Suction (VAC), 6 x 10A Power Outlets, 1 Network Socket, 1 Grounding Terminal
Accessories2 Equipment Shelves, 1 IV Pole & Infusion Pump Rack

Installation Guidelines for the YR02079

When installing the YR02079, follow these guidelines to ensure a successful setup:

  • Unboxing Checklist: Verify that all components are present, including the main pendant, mounting brackets, and accessories.
  • Anchoring: Securely anchor the pendant to the ceiling using appropriate hardware to withstand the maximum load capacity.
  • Leveling: Ensure the pendant is level to prevent operational issues.
  • Electrical Connections: Connect the necessary gas and power outlets according to the installation manual.
  • First Run Calibration: After installation, power up the unit and perform any required calibrations as per the user manual.

Environmental Conditions Required for the YR02079

To ensure the optimal performance of the YR02079, the installation site must meet specific environmental conditions:

  • Temperature Range: Maintain a temperature range of 20°C to 25°C for operational efficiency.
  • Humidity: Ensure that humidity levels do not exceed 70% to prevent damage to electrical components.
  • Voltage and Frequency: Use power sources that comply with standard voltage and frequency specifications to avoid malfunction.
  • Ventilation: Proper ventilation is essential to maintain air quality and prevent overheating.
  • Vibration Protection: The installation site must be free from excessive vibrations that could affect performance.

Site Preparation Checklist for YR02079 Installation

RequirementDetails
Power SupplyVerify that electrical outlets are installed and meet requirements.
Ceiling StructureEnsure the ceiling supports the weight and installation requirements.
Access to Gas OutletsConfirm the proximity to necessary gas connections.
Space ClearanceEnsure adequate space for the pendant's range of motion.

Common Installation Mistakes to Avoid

To ensure a successful installation of the YR02079, avoid the following common mistakes:

  • Improper anchoring that can lead to safety hazards.
  • Neglecting to level the pendant, which can affect its performance.
  • Failing to check for interference with other equipment or fixtures in the operating room.
  • Overlooking the calibration process which is vital for accurate operation.

Frequently Asked Questions

What are the specific environmental conditions for the YR02079 Operation Theatre Ceiling Pendant?

The YR02079 requires a temperature range of 20°C to 25°C, humidity levels not exceeding 70%, and a stable power supply that adheres to standard voltage and frequency specifications.

How do I ensure proper installation of the YR02079?

To ensure proper installation, follow a checklist that includes unboxing, secure anchoring, leveling, making electrical connections, and performing first run calibration.

What common issues might arise during the installation of the YR02079?

Common issues include improper anchoring, incorrect leveling, interference with other equipment, and failure to perform calibration.

Can the YR02079 be used in different clinical environments?

Yes, the YR02079 is versatile and can be effectively used in operating rooms, emergency rooms, intensive care units, and recovery areas.

What accessories come with the YR02079 Operation Theatre Ceiling Pendant?

The YR02079 comes with essential accessories including 2 equipment shelves and 1 IV pole & infusion pump rack.

What is the maximum load capacity of the YR02079?

The maximum load capacity of the YR02079 is 160 kg, ensuring it can support necessary medical equipment safely.

How can I request a quote for the YR02079?

You can easily request a quote for the YR02079 by contacting us through our online portal for competitive pricing and availability.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Operation Theatre Ceiling Pendant (w/o gas or power outlets) YR02079 with all specifications, dimensions, accessories and quote options.
View product datasheet →