Description
The Patient Monitors YR02176 is a state-of-the-art modular monitoring solution suitable for critical areas like Operating Theatres (OT) and Intensive Care Units (ICU). Featuring a 15-inch LCD screen, its versatile design allows easy tracking of essential parameters such as ECG, SPO2, TEMP, NIBP, RESP, and PR/HR. This model comes with a standard configuration of 5-lead ECG and other necessary monitoring capabilities. Optional enhancements include advanced functionalities like Masimo/Nellcor SpO2, Dual-IBP, and BIS, making it adaptable to various patient monitoring needs.
Market Price
Patient monitors like the YR02176 vary significantly in price depending on their features and capabilities. Typically, such models are priced between $4200 and $5100, placing them within a competitive range for high-quality medical equipment. It’s advisable to explore various offers and ensure a well-rounded purchase decision. For an exact quotation tailored to your specific requirements, consider using the Kalstein Plus platform for a seamless purchasing experience.
Frequently Asked Questions
What are the main uses of the Patient Monitors YR02176? The monitor is primarily used in OT and ICU settings to monitor a comprehensive range of vital signs, ensuring optimal patient care.
Can the monitor be customized? Yes, the monitor offers various optional configurations and modules to match specific monitoring needs, including advanced measurements like CO2 and IBP.
Is it easy to operate the monitor? Yes, the monitor is designed with user-friendly interfaces and settings, enabling healthcare professionals to use it efficiently.
Advantages and Disadvantages
The YR02176 offers numerous advantages, including high customization options, an intuitive display, and reliable measurements. However, its complexity might require additional training for optimal use. Additionally, the need for regular maintenance could be considered a potential downside for some facilities.
Field Usage
The Patient Monitors YR02176 are essential tools in medical settings where real-time data on a patient’s vital signs can mean the difference in critical decision-making. They are widely used in hospitals across the globe, from surgery rooms to emergency wards, providing invaluable data for healthcare providers.
Recommendations
It’s recommended to conduct regular maintenance checks to ensure accuracy and longevity of the patient monitor. Proper training for medical staff on using its modular capabilities can greatly enhance its benefits in the clinical environment.
Features
- 15-inch high-resolution LCD screen for clear, concise data visualization.
- Standard monitoring of ECG, SPO2, TEMP, NIBP, RESP, PR/HR.
- Extended options for high-level monitoring requirements such as CO2 and IBP.
Technical Specifications
Model | YR02176 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | x250, x500, x1000, x2000 | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 20~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |