The YR06206 Biological Safety Cabinet is an essential tool for ensuring maximum safety and efficiency in laboratories handling hazardous biological materials. To operate this equipment effectively, a strong understanding of its technical terminology and specifications is crucial. This guide will provide a comprehensive glossary of terms relevant to the YR06206, along with narrative explanations that relate these terms to the cabinet's functionalities and features.

Understanding the YR06206 Biological Safety Cabinet

The YR06206 is designed to meet the highest quality standards, providing a clean and safe working environment certified under the international standard ISO14644.1 Class 5. Its advanced HEPA filtration system ensures operator and environmental protection with an efficiency of 99.995%, while its downward airflow maintains exceptional precision with a variability of just ±0.015 m/s. Understanding the following terms can greatly enhance your ability to utilize this equipment effectively.

Technical Specifications of the YR06206

SpecificationDetails
ModelYR06206
Cleaning ClassificationInternational Standard ISO14644.1 Class 5
Inflow Velocity0.56 m/s
Downflow Velocity0.35 m/s
Downflow Velocity Accuracy±0.015 m/s
Noise Level (dB)≤65
Vibration≤3μm (X, Y, Z directions)
HEPA Efficiency99.995%
Light Intensity (LX)≥650
Pressure Differential Range (Pa)0-500
Operating EnvironmentAmbient temperature 10-30°C, relative humidity below 70%, no obvious vibration or dust
External Dimensions (mm)2120×1340×740
Work Zone Dimensions (mm)670×1260×560
Power SupplySingle-phase AC220V/50HZ
Power (W)350

Glossary of Technical Terms

TermDefinition
Biological Safety Cabinet (BSC)A ventilated cabinet designed to provide protection to the operator, the environment, and the product by filtering air through HEPA filters.
HEPA FilterA type of high-efficiency particulate air filter that captures at least 99.995% of particles.
ISO CertificationThe International Organization for Standardization certifies that products meet certain quality and safety standards.
DownflowThe airflow directed downwards to create a sterile environment within the cabinet.
InflowThe airflow that enters the cabinet to prevent contaminants from escaping.
VibrationUnwanted movement that can affect the stability and performance of laboratory equipment.
Ambient TemperatureThe temperature of the air surrounding the equipment, which can affect its performance.
Relative HumidityThe amount of moisture in the air relative to the maximum amount of moisture the air can hold at a given temperature.
Operating EnvironmentConditions such as temperature, humidity, and cleanliness required for the cabinet to function properly.
Power SupplyThe source of electrical energy required to operate the cabinet.
Noise LevelThe sound produced by the cabinet, measured in decibels (dB), which can impact the working environment.

Frequently Asked Questions

How does the HEPA filter in the YR06206 operate?

The HEPA filter in the YR06206 operates by trapping particles as air passes through it, providing a clean environment that minimizes contamination. With an efficiency of 99.995%, it ensures that even the smallest particles are removed from the airflow.

What is the significance of the ISO14644.1 Class 5 certification?

This certification signifies that the YR06206 meets stringent cleanliness standards, ensuring that the air quality within the cabinet is suitable for handling sensitive biological materials and experiments.

What should I do if the cabinet's airflow is inconsistent?

If you notice inconsistent airflow, check for obstructions in the filter or ductwork, ensure the cabinet is properly leveled, and inspect the fan operation for any mechanical failures.

How can I ensure the longevity of my YR06206 cabinet?

Regular maintenance is essential for the longevity of your cabinet. This includes routine inspections, filter replacements, and calibration of airflow settings to maintain optimal performance.

What environmental conditions are required for optimal operation of the YR06206?

The YR06206 operates best in an ambient temperature range of 10-30°C and relative humidity below 70%. It's important to avoid areas with excessive vibration or dust.

Are there any specific accessories recommended for the YR06206?

Yes, accessories such as additional HEPA filters and replacement lamps are recommended to maintain the cabinet's performance and ensure safety standards are upheld.

How do I properly calibrate the airflow in my YR06206 cabinet?

Calibration involves using specialized equipment to measure airflow rates and adjusting fan speeds accordingly. It is recommended to consult the user manual or a professional service for accurate calibration.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Biological Safety Cabinet YR06206 with all specifications, dimensions, accessories and quote options.
View product datasheet →