Description
The Multi-parameter Patient Monitor YR02178/YR02179 stands out as a vital tool for monitoring patient health in real-time, whether in the operating theater (OT) or intensive care unit (ICU). This semi-modular monitor features a reliable LCD screen and supports standard parameters including ECG, SPO2, TEMP, NIBP, RESP, and PR/HR making it an indispensable tool in medical practice. Additionally, its flexible configuration options—from touch screen variants to advanced diagnostic modules—enhance its adaptability to varied clinical needs.
Market Price
In the current market, multi-parameter patient monitors typically range from approximately 3,000 USD to 3,800 USD, depending on additional features and optional upgrades. This price range reflects the quality and technological sophistication typical of high-grade medical equipment like the YR02178/YR02179, offering excellent value for money in the realm of critical care solutions.
Frequently Asked Questions
- Is this monitor suitable for neonatal monitoring? Yes, the YR02178/YR02179 has adjustable heart rate and respiration settings to suit neonatal, pediatric, and adult patients.
- What is the difference between the YR02178 and YR02179 models? Both models share core functionalities, with differences typically in additional optional features or specific configurations.
- How often should the unit be calibrated? Regular calibration, ideally every six months, is recommended to maintain optimal performance.
Advantages and Disadvantages
Among the advantages of the YR02178/YR02179 are its comprehensive monitoring capabilities, modular design, and optional advanced features such as Masimo/Nellcor SpO2 for enhanced oxygen saturation analysis. On the downside, the learning curve for some advanced configurations might require additional training for medical staff.
Field Use
In practical scenarios, the YR02178/YR02179 monitors are deployed in both emergency and routine check-ups, providing healthcare professionals with continuous patient data. Its adjustable parameters and optional configurations aid in customizing the device for specific patient needs, enhancing its functionality in diverse clinical settings.
Recommendations
For optimal usage, it is recommended that users undergo training on the monitor’s features and configurations. Regular maintenance and updates are necessary to keep the system running efficiently. Institutions should consider opting for advanced modules if they cater to specialized medical requirements. For a detailed quote or further assistance, consider requesting a quotation through our Kalstein Plus platform.
Features
- Full-color LCD screen
- Multiple lead ECG configurations
- Advanced SPO2, NIBP, TEMP, and RESP monitoring
- Optional touch screen and thermal recorder
- Modular design for easy upgrades
Technical Specifications
Model | YR02178 | YR02179 | |
ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) | |
Connection method | I, II, III,AVR,AVL,AVF,V | ||
Lead Mode | 3 Leads (RA,LA,LL) | ||
Connection method | I, II,III | ||
Waveform | 1ch | ||
Gain | x250, x500, x1000, x2000 | ||
HR Range | Adult: 15~300bpm | ||
Neo/Ped | 15~350bpm | ||
Accuracy | ±1% or ±1bpm | ||
Resolution | 1bpm | ||
Sensitivity | >200(uVp-p) | ||
Differential input impedance | ≥5MΩ | ||
ST segment Monitoring Range | |||
Measure Range | -2.0~+2.0mV | ||
Measure Accuracy | -0.8mV~+0.8mV | ||
Heart Rate | Measuring range | 40~240bpm | |
Accuracy | ±3bpm | ||
Resolution | 1bpm | ||
Sensitivity | >200UVp-p | ||
Respiration | Method | Impedance between R-F(RA-LL) | |
Differential Input Impedance | >2.5MΩ | ||
Measuring Impedance Range | 0.3~3.0 MΩ | ||
Base line Impedance Range | 200~4000Ω | ||
Bandwidth | 0.1~2.5Hz | ||
Resp. Rate | Adult: 7~120BrPM | ||
Neo/Ped | 7~150BrPM | ||
Resolution | 1 BrPM | ||
Accuracy | ±2 BrPM | ||
Alarm | 10~40S | ||
NIBP | Method | Oscillometric | |
Mode | Manual/Auto/STAT | ||
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | ||
Measuring Period in STAT Mode | 5 Min | ||
Pulse Rate Range | 40~240bpm | ||
Alarm Type | SYS, DIA, MEAN | ||
Resolution | |||
Pressure | 1mmHg | ||
Accuracy | Maximum Mean error: 5mmHg | ||
Maximum Standard deviation | 8mmHg | ||
SPO2 | Display | Number of SPO2,waveform of capacity,Pulse | |
Measuring range | 0~100% | ||
Resolution | 1% | ||
Accuracy | 70~99% (±2%) | ||
Alarm system | Audio-video alarm | ||
Pulse rate range | 0~300bpm | ||
TEMP | Channel | 2 | |
Measuring and Alarm Range | 0~50ºC | ||
Resolution | 0.1ºC | ||
Accuracy | 0.1ºC | ||
Actualization interval | about 1 Second. | ||
Average Time Constant | <10 Second. |